AEL steel solvent storage building inside a plant, with a technician wheeling a drum toward flammable-liquid cabinets

FCS™ Series flammable storage

Solvent and flammable liquid storage buildings

Prefabricated steel buildings for ethanol, isopropyl alcohol, hexane and other Class I solvents, with explosion-resistant exhaust and fire suppression installed before delivery.

Solvent storage buildings: a dedicated, ventilated steel building for the drums, totes and safety cans that feed solvent processing, coating, blending and lab work. Bulk inventory moves out of the process room and away from people, into a space designed for it.

Built in-house: AEL is fully vertically integrated. Control panels, electrical, plumbing, HVAC and mechanical work, fire-suppression installation (dry chemical and clean agent systems), welding, sheet metal fabrication, powder coating and our own insulated wall panels are all produced by our own team. AEL is also an approved Stat-X distributor. See our in-house capabilities.

AEL FCS Series flammable container storage building with two personnel doors, NFPA 704 diamonds, flammable placards and louvered vents

Why a separate building

Process rooms are sized for the work, not the inventory.

When a week of ethanol or hexane sits in drums along the wall of a C1D1 room, or in a general warehouse aisle, it adds fuel load to a space that was never planned for it and complicates the conversation with your fire marshal about maximum allowable quantities.

A storage building takes that inventory out of the process area: an explosion-resistant exhaust fan pulling vapor out of the space, and alarms that report to your facility system. The process room keeps what the shift needs.

AEL builds both sides of that line, from solvent processing enclosures to hazardous location enclosures (C1D1/C1D2), so storage and process controls can be planned together.

Construction

What is built into every FCS™ storage building.

Steel structure and finishes

Heavy-duty, non-combustible steel construction with a weather-tough exterior finish and forklift pockets for setting and relocating the building.

Secondary containment (option)

Available as an option: a graded floor with a sump pump, so a leaking drum or tote stays inside the building.

Ventilation

Explosion-resistant mechanical ventilation, engineered around the solvents you store to keep vapors from building up.

Fire suppression

Dry chemical suppression is standard. Stat-X condensed aerosol and clean agent systems are available as upgrades, installed by our own technicians. AEL is an approved Stat-X distributor.

Electrical and controls

Factory-wired electrical and safety controls with visual and audible alarms, built with UL or ETL (Intertek) listed components and ready to tie into your facility system.

Floor, doors and grounding

Epoxy flooring as standard (custom flooring available, including anti-static), grounding and bonding points for drum transfer, and NFPA hazard-diamond signage. Doors: one 3′ × 7′ single man door with lock and key, panic hardware and self-closer as standard unless otherwise specified; double doors on the long side (two 3′ × 7′), 40–42 in. wide man doors, multiple sets of single or double doors, key fob entry, electric locks and fail-safe safety door locks available.

Wall and ceiling assemblies are built to NFPA standards using non-combustible, fire-resistive materials. Two levels are available:

  • Standard fire-assembly construction: non-combustible, fire-resistive wall and ceiling assemblies for typical industrial storage.
  • Enhanced fire-assembly construction: a stronger separation option for sites that need more protection between stored solvents and the people, buildings and equipment around them. Ask us how it is built.

We do not claim an hourly fire-resistance rating for these assemblies. If your code path requires a listed, hourly-rated assembly, that decision belongs to your design professional and the AHJ, and we will tell you at the quote stage what our construction does and does not document.

The design basis is NFPA 30, the Flammable and Combustible Liquids Code, together with the flammable-liquids chapter of the International Fire Code as adopted where you are. Final code compliance, permitting and acceptance rest with the owner and the authority having jurisdiction.

8 × 10 ft 80 sq ft
8 × 20 ft 160 sq ft
8 × 30 ft 240 sq ft
8 × 40 ft 320 sq ft
10 × 10 ft 100 sq ft
10 × 20 ft 200 sq ft
10 × 30 ft 300 sq ft
10 × 40 ft 400 sq ft

Custom sizes are available. Wider units may need special permits to ship or to set on site. Floor areas are nominal exterior footprints.

AEL solvent storage building with sliding doors open to blue drums on racking above IBC totes, forklift nearby

Forklift or drum-truck access

Drums on racking

Drum racking and shelving arranged for forklift or drum-truck access through optional double doors on the long side.

Interior of an AEL flammable storage building with IBC totes standing on grating over a containment sump

Optional sump floor

IBC totes over containment

A building fitted with the optional graded sump floor: totes on grating over the sump, with aisle space for a pallet jack.

Technician moving a drum into an AEL storage building fitted with flammable-liquid cabinets and shelving

Transfer inside the building

Active dispensing

Dispensing from drums or totes inside the building, with grounding and bonding at the transfer point and ventilation planned for open-container work.

Most solvent storage buildings are set outdoors on a level pad, at the separation distance your AHJ requires from other buildings and property lines. Where there is no room outside, ask us about placing an FCS™ building inside a larger structure; your AHJ has to accept the arrangement and exhaust has to be ducted to the exterior.

  1. Inventory

    Solvent names and SDS, container types (drums, totes, safety cans), and the maximum quantity you expect to keep on hand.

  2. Use

    Storage only or dispensing inside the building, how often containers move, and any temperature limits for the materials.

  3. Site

    Location and pad, distance to other buildings and property lines, available power, and the delivery route.

  4. Review comments

    Anything already received from your AHJ, fire-protection engineer or insurer, including suppression or construction requirements.

Have your footprint? Get a quote for this footprint

Solvent storage FAQ

Questions before you specify a storage building.

Which solvents can an FCS storage building hold?

FCS™ buildings are configured for Class IA, IB and IC flammable liquids. That covers common process solvents such as ethanol, methanol, isopropyl alcohol, acetone, hexane, heptane and xylene. Oxidizers, acids and other incompatible materials need their own segregation plan; send your full inventory and we will flag conflicts during the review.

Can it store propane or butane cylinders?

Liquefied gases such as propane and butane fall under different requirements than flammable liquids, typically NFPA 58 and the LP-gas chapter of the fire code. They are not part of the standard FCS™ configuration. If your process uses them, tell us early so storage for both can be planned with your AHJ.

What fire-resistive construction does the building use?

Wall and ceiling assemblies are built to NFPA standards with non-combustible, fire-resistive materials, in standard and enhanced versions. We do not claim an hourly fire-resistance rating. If your code path requires a listed hourly-rated assembly, your design professional and AHJ decide that, and we will be clear about what our construction documents.

How is secondary containment handled?

Epoxy flooring is standard. A graded floor with a sump pump is available as an option, with grating where totes or drums sit. The required capacity depends on the containers and the code edition your AHJ enforces, so we confirm it against your inventory during design.

How far does the building need to be from other structures?

Separation depends on the quantity and class of liquid stored, the building construction and the fire code edition adopted locally. Your AHJ sets the distance; once your project is ordered, we provide the drawings and system information they need to make that call.

Can the storage building tie into our processing room controls or alarms?

Yes. Visual and audible alarms and automatic ventilation controls are standard, with alarm outputs for your facility system. The control enclosure is built by the same in-house panel shop that builds our AEL CORE control panels, which makes coordinating storage and process alarms simpler.

What fire suppression is included?

Dry chemical suppression is standard. Stat-X condensed aerosol and clean agent systems are available as upgrades, and our technicians install all three. AEL is an approved Stat-X distributor.

Get a quote

Send the solvent list and the site.

We will come back with a building size, the systems it needs and the documentation list for your AHJ. Prefer to talk first? Call 888-502-6695.

  • Built in-house: fabrication, electrical, controls and suppression by our own team.
  • Approved Stat-X distributor.
  • Factory testing, documented as specified.

Financing available. Explore equipment financing and leasing options

  • Talk to an engineer (888) 502-6695
  • Location 1402 Airport Blvd, Santa Rosa, CA 95403
  • Hours Mon – Fri, 8AM – 6PM PT

Fields marked are required. Everything else is optional.

Your details

We reply here. No newsletters.

For a quicker call-back.

Your project

A model, series or solution, e.g. Sentinel Mini 40.

Dimensions, site conditions, equipment, timeline: anything that helps us plan it.

An engineer, not a call center, replies within one business day. We never share your details.

Get a Quote