Solvent storage buildings: a dedicated, ventilated steel building for the drums, totes and safety cans that feed solvent processing, coating, blending and lab work. Bulk inventory moves out of the process room and away from people, into a space designed for it.
Built in-house: AEL is fully vertically integrated. Control panels, electrical, plumbing, HVAC and mechanical work, fire-suppression installation (dry chemical and clean agent systems), welding, sheet metal fabrication, powder coating and our own insulated wall panels are all produced by our own team. AEL is also an approved Stat-X distributor. See our in-house capabilities.
Why a separate building
Process rooms are sized for the work, not the inventory.
When a week of ethanol or hexane sits in drums along the wall of a C1D1 room, or in a general warehouse aisle, it adds fuel load to a space that was never planned for it and complicates the conversation with your fire marshal about maximum allowable quantities.
A storage building takes that inventory out of the process area: an explosion-resistant exhaust fan pulling vapor out of the space, and alarms that report to your facility system. The process room keeps what the shift needs.
AEL builds both sides of that line, from solvent processing enclosures to hazardous location enclosures (C1D1/C1D2), so storage and process controls can be planned together.
Construction
What is built into every FCS™ storage building.
Wall and ceiling assemblies are built to NFPA standards using non-combustible, fire-resistive materials. Two levels are available:
- Standard fire-assembly construction: non-combustible, fire-resistive wall and ceiling assemblies for typical industrial storage.
- Enhanced fire-assembly construction: a stronger separation option for sites that need more protection between stored solvents and the people, buildings and equipment around them. Ask us how it is built.
We do not claim an hourly fire-resistance rating for these assemblies. If your code path requires a listed, hourly-rated assembly, that decision belongs to your design professional and the AHJ, and we will tell you at the quote stage what our construction does and does not document.
The design basis is NFPA 30, the Flammable and Combustible Liquids Code, together with the flammable-liquids chapter of the International Fire Code as adopted where you are. Final code compliance, permitting and acceptance rest with the owner and the authority having jurisdiction.
| 8 × 10 ft | 80 sq ft |
|---|---|
| 8 × 20 ft | 160 sq ft |
| 8 × 30 ft | 240 sq ft |
| 8 × 40 ft | 320 sq ft |
| 10 × 10 ft | 100 sq ft |
| 10 × 20 ft | 200 sq ft |
| 10 × 30 ft | 300 sq ft |
| 10 × 40 ft | 400 sq ft |
Custom sizes are available. Wider units may need special permits to ship or to set on site. Floor areas are nominal exterior footprints.
Forklift or drum-truck access
Drums on racking
Drum racking and shelving arranged for forklift or drum-truck access through optional double doors on the long side.
Optional sump floor
IBC totes over containment
A building fitted with the optional graded sump floor: totes on grating over the sump, with aisle space for a pallet jack.
Transfer inside the building
Active dispensing
Dispensing from drums or totes inside the building, with grounding and bonding at the transfer point and ventilation planned for open-container work.
Most solvent storage buildings are set outdoors on a level pad, at the separation distance your AHJ requires from other buildings and property lines. Where there is no room outside, ask us about placing an FCS™ building inside a larger structure; your AHJ has to accept the arrangement and exhaust has to be ducted to the exterior.
-
Inventory
Solvent names and SDS, container types (drums, totes, safety cans), and the maximum quantity you expect to keep on hand.
-
Use
Storage only or dispensing inside the building, how often containers move, and any temperature limits for the materials.
-
Site
Location and pad, distance to other buildings and property lines, available power, and the delivery route.
-
Review comments
Anything already received from your AHJ, fire-protection engineer or insurer, including suppression or construction requirements.
Have your footprint? Get a quote for this footprint
Solvent storage FAQ
Questions before you specify a storage building.
Which solvents can an FCS storage building hold?
FCS™ buildings are configured for Class IA, IB and IC flammable liquids. That covers common process solvents such as ethanol, methanol, isopropyl alcohol, acetone, hexane, heptane and xylene. Oxidizers, acids and other incompatible materials need their own segregation plan; send your full inventory and we will flag conflicts during the review.
Can it store propane or butane cylinders?
Liquefied gases such as propane and butane fall under different requirements than flammable liquids, typically NFPA 58 and the LP-gas chapter of the fire code. They are not part of the standard FCS™ configuration. If your process uses them, tell us early so storage for both can be planned with your AHJ.
What fire-resistive construction does the building use?
Wall and ceiling assemblies are built to NFPA standards with non-combustible, fire-resistive materials, in standard and enhanced versions. We do not claim an hourly fire-resistance rating. If your code path requires a listed hourly-rated assembly, your design professional and AHJ decide that, and we will be clear about what our construction documents.
How is secondary containment handled?
Epoxy flooring is standard. A graded floor with a sump pump is available as an option, with grating where totes or drums sit. The required capacity depends on the containers and the code edition your AHJ enforces, so we confirm it against your inventory during design.
How far does the building need to be from other structures?
Separation depends on the quantity and class of liquid stored, the building construction and the fire code edition adopted locally. Your AHJ sets the distance; once your project is ordered, we provide the drawings and system information they need to make that call.
Can the storage building tie into our processing room controls or alarms?
Yes. Visual and audible alarms and automatic ventilation controls are standard, with alarm outputs for your facility system. The control enclosure is built by the same in-house panel shop that builds our AEL CORE control panels, which makes coordinating storage and process alarms simpler.
What fire suppression is included?
Dry chemical suppression is standard. Stat-X condensed aerosol and clean agent systems are available as upgrades, and our technicians install all three. AEL is an approved Stat-X distributor.
Related storage and process pages
Get a quote
Send the solvent list and the site.
We will come back with a building size, the systems it needs and the documentation list for your AHJ. Prefer to talk first? Call 888-502-6695.
- Built in-house: fabrication, electrical, controls and suppression by our own team.
- Approved Stat-X distributor.
- Factory testing, documented as specified.
Financing available. Explore equipment financing and leasing options
- Talk to an engineer (888) 502-6695
- Location 1402 Airport Blvd, Santa Rosa, CA 95403
- Hours Mon – Fri, 8AM – 6PM PT
Request received.
Thank you. An AEL representative will review your request and reach out to you soon.
Your inquiry:
What happens next
- Engineering review. An AEL engineer reads your request and checks it against the right product line.
- We reach out within one business day. By email or phone, to confirm details, site conditions and timeline.
- Specs and pricing. You receive pricing and the key specifications for your configuration. Project drawings are prepared once an order is placed.