Indoor Hazardous Location Rooms

Custom indoor C1D1 and C1D2 rooms, built to your dimensions.

Modular rooms for flammable gas and vapor work inside your building, configured around your process and area classification.

Long white AEL modular double-wall room with a windowed door and safety signage inside a warehouse Expand photo

A classified room inside the building you already have

An indoor hazardous location room sets a defined C1D1 or C1D2 space inside an existing plant, lab or warehouse. AEL builds it as a modular room, single-wall or double-wall, using the same construction family and component types as our solvent-processing lineup, then configures it for your classification, process and floor space.

The room pictured is a modular double-wall room built with non-combustible panels.

Rooms are typically built to the customer’s footprint and ceiling height rather than a fixed catalog size, so the layout follows your equipment, doors and access paths.

Why build the hazardous area indoors

Keeping the classified space inside the main building puts it next to the people, utilities and workflow it serves. Staff move between general and classified areas without crossing a yard, the room shares the building’s security and climate, and power, water and exhaust runs can be shorter.

An indoor C1D1 room also lets you isolate one hazardous step, such as solvent handling, chemical dispensing, fuel or energy-materials R&D, or a pilot process, instead of classifying an entire production area. Exhaust routing, roof or wall penetrations and building fire-code requirements are reviewed as part of the project.

Single-wall rooms suit most indoor installs where the building provides weather protection. Double-wall panels add rigidity and room for insulation or concealed routing. The right choice depends on process, finish and code requirements, and is confirmed during engineering review.

Fire-resistance-rated construction may be required when an indoor hazardous-materials space is treated as a control area under the adopted building and fire codes, typically the International Building Code (IBC) and International Fire Code (IFC). Those codes separate control areas with fire barriers and horizontal assemblies, and the fire-resistance rating that applies depends on the materials and quantities (including maximum allowable quantities), how the space is used, the story and building construction type, separation from other areas, and the code edition your authority having jurisdiction (AHJ) has adopted. A panel hour rating is not the same thing as a complete fire-rated assembly, and electrical hazardous-location classification (such as Class I, Division 1 or 2) is separate from fire-resistance hours. For indoor controlled areas, AEL can include optional fire-rated paneling in 60-minute, 90-minute, and 2- or 3-hour configurations when the project calls for it. A photograph of the room does not establish a fire-hour panel or assembly rating; confirm the required paneling or assembly for the project with your engineer and AHJ.

Hazardous-location heaters and hazardous-location air conditioning can be added where the process or room climate calls for them. Heating and cooling equipment is selected to suit the room’s classification and is confirmed during engineering review.

Your engineer and the authority having jurisdiction (AHJ) set the final area classification. AEL configures ventilation, gas detection, controls and electrical around that basis and can prepare documentation such as drawings, equipment schedules and ventilation information for review.

Class I covers flammable gases and vapors. Division 1 (C1D1) is where ignitable concentrations can exist during normal operation, or frequently because of repair, maintenance or leakage. Division 2 (C1D2) is where those materials are normally confined in closed containers or systems, or kept below ignitable levels by mechanical ventilation, so an ignitable atmosphere is expected only if containment or ventilation fails, or where the area borders a Division 1 space. AEL rooms on this page are scoped for Class I, Division 1 or Division 2 projects.

Class II covers combustible dust. Division 1 (C2D1) is where dust can be suspended in the air in ignitable amounts during normal operation, or where electrically conductive dusts are present. Division 2 (C2D2) is where dust is not normally suspended, but layers or accumulations could ignite or be released during abnormal operation. Dust is a different hazard from gas and vapor, with its own equipment and design requirements, so dust-classified projects need a separate engineering review before scope is confirmed.

For more on the codes and room requirements, read C1D1 vs C1D2 requirements.

The owner’s engineer and the AHJ determine the classification from the materials, quantities, process and ventilation. AEL then configures the room around that classification.

Yes. Indoor rooms are usually built to the customer’s dimensions. Share your floor plan, clear height and door access, and we will review the layout.

Yes. If the hazard should stay outside the main building, see outdoor C1D1 and C1D2 enclosures. Solvent-extraction buyers can also compare the solvent processing series.

Brochure

Instant Document Access

Document access

Complete this brief form to instantly download the document and connect with our engineering team.

Get a quote

Let’s scope
your project.

Tell us about your application and timeline. Our team — not a call center — responds within one business day.

  • Built in-house: fabrication, electrical, controls and suppression by our own team.
  • Approved Stat-X distributor.
  • Factory testing, documented as specified.

Financing available. Explore equipment financing and leasing options

  • Talk to an engineer (888) 502-6695
  • Location 1402 Airport Blvd, Santa Rosa, CA 95403
  • Hours Mon – Fri, 8AM – 6PM PT

Fields marked are required. Everything else is optional.

Your details

We reply here. No newsletters.

For a quicker call-back.

Your project

A model, series or solution, e.g. Sentinel Mini 40.

Dimensions, site conditions, equipment, timeline: anything that helps us plan it.

An engineer, not a call center, replies within one business day. We never share your details.

Get a Quote