If your batteries fit on shelves and the storage can stay indoors, start with a cabinet. If they arrive on pallets or racks, need charging, or have to live outside, you need a walk-in enclosure. If the batteries will be wired up and running as an energy storage system, you need a BESS enclosure, and that is a different kind of project.
We build all three in Santa Rosa, California: the Sentinel Mini cabinet, the Sentinel walk-in (as an outdoor container or an indoor room) and the EnergyCube for battery integrators. Whichever one fits, your local fire marshal or other authority having jurisdiction (AHJ) has the final say on the installation, so bring them in early.
Reviewed by Christian Hluz, Owner, AEL – Advanced Extraction Labs · Last reviewed: October 2026
The questions that decide it
These are the questions our engineers work through on a first call. You don’t need every answer before you contact us, but each one gets you closer to the right enclosure.
Inside the building or out in the yard?
With yard space and room to keep it away from your buildings, an outdoor Sentinel container is usually the simplest route.
Indoor storage makes sense when there’s no yard to spare, when the batteries have to stay behind the same locked doors as the rest of your parts, or when they need to sit right next to the service bay or the UPS room. Moving inside means working out where the exhaust leaves the building, how our alarms reach your fire alarm panel, what your sprinklers do and what the slab will carry.
One rule up front: Sentinel Mini cabinets are for indoor use only. If the storage has to be outside, you’re looking at a walk-in.
What batteries, and what shape are they in?
Chemistry is only part of the picture. We review lithium-ion and LiFePO4 batteries alike, but we also need the battery’s dimensions, weight, energy and state of charge, the manufacturer’s storage guidance, and whether anything will be charged.
Condition matters more than most buyers expect. Pallets of new modules from the supplier are one job. A recalled pack, or one pulled from a damaged vehicle, is another. The handling procedure for damaged or recalled batteries should come from the battery maker, your safety team and the AHJ, and we configure the enclosure around it. Tell us early if any of your inventory falls into that group.
How many, and how fast do they move?
Flow matters more than the count. A parts room that pulls two modules a day needs a different enclosure than a UPS refresh that stages forty at once.
Some cabinets are sold with one kWh cap printed on the spec sheet. We don’t put one universal energy limit on our cabinets, because battery energy, size, quantity, condition and what you’re doing with them all interact. Quantity can also change which permits and reviews apply to you. That’s one more reason to call your AHJ before you order.
Where does the off-gas go?
A lithium-ion battery in thermal runaway gives off toxic gas, and the enclosure has to get it out.
In a Sentinel, the gas detection is wired to the emergency exhaust, so the fans come on by themselves when the sensors pick something up. On an indoor build we duct that exhaust out of the building. It never dumps into your shop. The Mini works differently. The standard cabinet has perimeter door seals and side louvers but no active exhaust, and we add our CP2000 ventilation package when the application calls for it.
Who knows when something goes wrong?
Detection buys people time. Every Sentinel ships with gas detection tied to the ventilation, visual and audible alarms, and an emergency purge button at the door. We add early-warning thermal detection when the project calls for it, and indoor rooms tie into your building’s fire alarm panel. Which detection your site needs is up to your AHJ and your fire protection engineer.
The AEL CORE control panel is built to UL 508A in our own panel shop. On its tower light, red means check airflow. Amber with the horn means the enclosure is purging. No light means everything is normal.

What puts out a fire, and what can’t it do?
Sentinel comes with dry chemical suppression as standard. Stat-X condensed aerosol and clean agent systems are available, and we review water sprinkler options project by project. Stat-X is an option on the Mini, and the EnergyCube can be built with dry chemical, clean agent, aerosol or water sprinkler systems. We’re an approved Stat-X distributor and our own technicians install the suppression, so it’s planned with the enclosure from the start.
Be realistic about what suppression is for. Our fire protection options are meant for early response and for isolating the hazard. We don’t claim that any enclosure will stop or prevent thermal runaway.
How far from everything else?
Separation from buildings, property lines, exits and other storage often settles the indoor-or-outdoor question before anything else does. The distances for your site come from your AHJ, not from us. Send a site plan or floor plan early and we’ll lay out the racking, aisles, doors and service clearances to fit.
Will you charge batteries in there?
Tell us on the first call. Charging adds electrical load and heat, and it changes how we size the ventilation and detection. Our charging add-on for Sentinel gives you dedicated circuits sized to the chargers you name, charger mounting planned with the racking so cords stay off the floor, and charging power that cuts out on a gas, heat or ventilation alarm.
Power comes factory-wired and sized to your site, with three-phase available. Our panels use UL or ETL listed components, and HVAC is sized to the battery heat load and your climate.
What will the fire marshal want to see?
Two codes deal with lithium battery storage directly: the 2024 International Fire Code, Section 320 (Lithium-Ion and Lithium Metal Battery Storage), and NFPA 855, 2026 edition, Chapter 14 (Storage of Lithium Metal or Lithium-Ion Batteries). In broad terms they cover how batteries are stored and arranged, separation, detection and alarms, ventilation and fire suppression. Read the official text on the ICC website and the NFPA 855 page rather than relying on anyone’s summary, ours included.
Your local AHJ, usually the fire marshal, decides which edition applies, what your site needs and whether the installation is approved. Jurisdictions adopt new editions on their own schedule, often with local changes.
Two terms get mixed up a lot. NFPA 855 is a standard for installations, so no product is “certified” to it. UL 9540A is a fire test method that battery and system makers run on their own products. If your AHJ asks for that data, it comes from your battery supplier.
Sentinel and EnergyCube enclosures are designed and built to UL 1487 and NFPA 855 standards. Sentinel walk-ins can be built as 1-, 2- or 3-hour fire assemblies, depending on what your local fire authority requires. For your project we prepare the information reviewers ask for: the layout and elevations, your battery information, the ventilation basis, detection and suppression descriptions, the electrical one-line and separation details. Stamped drawings are available as an option.
Can you get it to the spot?
An outdoor Sentinel leaves Santa Rosa with the ventilation, detection, suppression and AEL CORE panel already installed, sitting on a heavy-duty steel base that’s ready to set and relocate. Plan a truck route and a prepared pad.
Indoor Sentinel rooms go together differently. We make the insulated wall panels in our own shop and assemble the room on your slab, so nothing has to be craned over the roof. Before we build, we check door widths, clear height and what the slab can carry.
Sentinel Mini cabinets sit on a fabricated base that a pallet jack slides under. They run from 43 to 80 inches tall, so measure your doorways.

Cabinet, walk-in or BESS enclosure: how they compare
Here is how our three lines line up. We confirm the final configuration on every order.
| Cabinet (Sentinel Mini) | Walk-in (Sentinel and Indoor Sentinel) | BESS enclosure (EnergyCube) | |
|---|---|---|---|
| Built for | Service, warranty and parts inventory that fits on shelves | Rack and pallet storage, staging, isolation and charging | Batteries installed and running as an energy storage system |
| Where it goes | Indoors only | Outdoor yard or pad, or built inside your building | Utility, commercial and industrial, and remote sites |
| Access | Through the doors, to perforated steel shelves | Walk-in, or rack access through the doors on indoor builds | Doors, aisles and clearances set by the integrator’s layout |
| Sizes | Five models, Mini 30 to Mini 100, 43 to 80 in. tall | 8×10, 8×20 and 8×40 ft (9 ft high), custom, or built to your room | Custom, around the integrator’s rack layout |
| Ventilation | Seals and louvers; CP2000 ventilation optional | Emergency exhaust linked to gas detection, ducted outside on indoor builds | Gas detection and ventilation interlocks, HVAC or liquid-cooling ready |
| Suppression | Stat-X optional | Dry chemical standard; Stat-X, clean agent or sprinkler options | Dry chemical, clean agent, aerosol or water sprinkler options |
| Controls | Optional external control and monitoring | AEL CORE panel built to UL 508A, alarms and emergency purge | Control panels built to UL 508A and BMS interfaces as specified |
Have this ready when you call
- Battery make, model, dimensions, weight and energy
- How many you hold and how often they come and go
- Any damaged, recalled or end-of-life batteries, and the state of charge
- If you’ll charge inside, the charger make, model and quantity
- A site plan or floor plan showing where the enclosure would go
- Available power, plus your fire alarm and sprinkler details
- The delivery route, door sizes and clear height
- Your AHJ and any questions they’ve already raised
Talk to the people who build it
AEL – Advanced Extraction Labs does its own fabrication, wiring, controls and suppression in Santa Rosa, so the engineer you talk to can answer for the whole unit. Send us what you have and an engineer, not a call center, will get back to you within one business day.
Ready to scope your battery storage? Get a quote
See the product pages for Sentinel Mini cabinets (models 30, 40, 60, 80 and 100), Sentinel walk-in containers, Indoor Sentinel rooms and EnergyCube BESS enclosures. Dealers can start with battery isolation for auto dealerships.
Frequently asked questions
What’s the difference between a battery storage cabinet and a walk-in container?
Scale and access. A cabinet holds batteries on shelves and you reach in through the doors; our Sentinel Mini cabinets are indoor only. A walk-in is a room people and carts go into, with the ventilation, detection, alarms and suppression wired together.
When do I need a BESS enclosure instead?
When the batteries will be installed and running as an energy storage system, tied to inverters and power electronics. Sentinel is for batteries you’re storing, staging, isolating or charging. EnergyCube is the enclosure we build for integrators who supply the batteries and electronics themselves.
Which codes cover lithium battery storage?
The 2024 International Fire Code, Section 320, and NFPA 855, 2026 edition, Chapter 14, both deal with it directly. Your local AHJ, usually the fire marshal, decides which edition applies and what your site needs, and approves the installation.
Can damaged or recalled batteries go in with new stock?
Plan for them separately. The battery maker’s guidance, your safety team and the AHJ should set the handling procedure for damaged or recalled batteries, and we configure the enclosure to match. Bring it up on the first call.
Is your enclosure NFPA 855 certified?
No product is. NFPA 855 is a standard for installations, and the AHJ approves installations. Our Sentinel and EnergyCube enclosures are designed and built to UL 1487 and NFPA 855 standards, and we prepare the documents your AHJ asks for.
This article is general information, not a code review of your project. Your AHJ sets the requirements for your site.